NeuroFluidics™ Line.

6 Products with 4 architectures and 2 options.

Our NeuroFluidics™ line offers a variety of microfluidic devices and related applications, with its 4 architectures and 2 options.

dualink
DuaLink

For 2 co-cultures & enhanced fluidic isolation

Explore
dualinkshift
DuaLink Shift

For synaptic isolation & enhanced fluidic isolation

Explore
trialink
TriaLink

For 3 co-cultures & enhanced fluidic isolation

Explore
dualinkultra
DuaLink Ultra

For 2 co-cultures & enhanced axonal projection

Explore
dualinkdeltaultra
DuaLink Delta Ultra

For growth kinetics & enhanced axonal projection

Explore
trialinkultra
TriaLink Ultra

For 3 co-cultures & enhanced axonal projection

Explore

DuaLink.

Specially designed for 2 co-cultures & fluidic isolation.

With the DuaLink microfluidic chip, microchannels tunnels and HT format NeoBento™ technologies are combined in a single chip to provid an unparalleled user experience combined with an enhanced fluidic isolation.

• 3 compartments : 2 for cell culture & 1 for fluidic isolation
• 4 up to 16 microfluidic chips per NeoBento
• Co-culture of different cell types
• Compartmentalization
• Fluidic isolation
•Discontinious connectivity by microchannels tunnels technology





.
All our chips are in the NeoBento™ format (standard 96-well SBS plate format) and thus offer a variety of handling readouts for your different needs.

Imaging
• Immunofluorescence
• Calcium Imaging
• Live staining
• Live Dead Assays
 
Biochimic analysis
• Lysis cells analysis
• Supernatant analysis
• ELISA
• Liquid chromatography
• Mass Spectoscopy


.
DuaLink is specially designed to co-culture 2 cell types in channel 1 and 3 and allow fluidic isolation between the 3 channels.

In-vitro models
Innervated skin 2D
Sensitive skin
Indications
• Neurological Troubles (AD, PD, ALS, MS)
• Skin nociception
Field
• Toxicology
• Virology
• Neuroinflammation
• Itch
• Ageing
Capabilities
• Axonal transport
• Co-culture & compartmentalization
Our aim is to translate physiological behaviors by integrating our technologies within one chip.

Microchannels tunnels: Due to their micrometric measurements, only cell extensions can grow within the microchannels, leaving the cell bodies within the compartments themselves, that allow an enhanced fluidic isolation and discontinuous connectivity between compartments.

NeoBento™ HT Format: The NeoBento is our versatile container which is in the standard 96-well microplate format, compatible with standard liquid handling and imaging equipment, and does not require expensive equipment. The NeoBento™ makes NETRI’s microfluidic devices as versatile and easy to handle as a typical 96-well plate.




.

DuaLink Shift.

Specially designed for 2 co-cultures & synaptic isolation.

With the DuaLink Shift microfluidic chip, microchannels tunnels and HT format NeoBento™ technologies are combined in a single chip to provid an unparalleled user experience combined with the creation of synaptic compartment.

• 3 compartments: 2 for cell culture & 1 for synaptic isolation
• 8 or 16 microfluidic chips per NeoBento™
• Synapse isolation in the middle channel
• Asymmetrical shape with microchannels of different length (shorter length between the first and second channel than between the second and third channel)
• Discontinious connectivity by microchannels tunnels technology




.
All our chips are in the NeoBento™ format (standard 96-well SBS plate format) and thus offer a variety of handling readouts for your different needs.

Imaging
• Immunofluorescence
• Calcium Imaging
• Live staining
• Live Dead Assays
  Biochimic analysis
• Lysis cells analysis
• Supernatant analysis
• ELISA
• Liquid chromatography
• Mass Spectoscopy



.
DuaLink Shift is specially designed to isolate synaptic connections in channel 2 and allow fluidic isolation between the 3 channels.

Indications
• Huntington Disease
• Alzheimer Disease – Glutamate
• Parkinson Disease – αsyn
Field
• Neuroinflammation
• Neuro-immunology
• Synaptic Transmission
Capabilities
• Synaptic isolation
• Co-culture & compartmentalization
• Axonal transport


.
Our aim is to translate physiological behaviors by integrating our technologies within one chip.

Microchannels tunnels: Due to their micrometric measurements, only cell extensions can grow within the microchannels, leaving the cell bodies within the compartments themselves, that allow an enhanced fluidic isolation and discontinuous connectivity between compartments.

NeoBento™ HT Format: The NeoBento is our versatile container which is in the standard 96-well microplate format, compatible with standard liquid handling and imaging equipment, and does not require expensive equipment. The NeoBento™ makes NETRI’s microfluidic devices as versatile and easy to handle as a typical 96-well plate.




.

TriaLink.

Specially designed for 3 co-cultures & fluidic isolation.

With the TriaLink microfluidic chip, microchannels tunnels and HT format NeoBento™ technologies are combined in a single chip to provid an unparalleled user experience combined with the ability to culture up to 3 different cell types.

• 3 compartments for independant 3 different cell type cultures
• 8 or 16 microfluidic chips per NeoBento™
• Up to tri-culture of 3 different cell types
• Discontinuous connectivity by microchannels tunnels technology







.
All our chips are in the NeoBento™ format (standard 96-well SBS plate format) and thus offer a variety of handling readouts for your different needs.

Imaging
• Immunofluorescence
• Calcium Imaging
• Live staining
• Live Dead Assays
  Biochimic analysis
• Lysis cells analysis
• Supernatant analysis
• ELISA
• Liquid chromatography
• Mass Spectoscopy



.
TriaLink is specially designed to co-culture 3 cell types in channel 1, 2 and 3, and allow fluidic isolation between the 3 channels.

Indications
• Multiple sclerosis
• Cerebral tumors
Field
• Neuroinflammation
• Gut-Brain-Axis
Capabilities
• Co-culture & compartmentalization
• Axonal transport





.
Our aim is to translate physiological behaviors by integrating our technologies within one chip.

Microchannels tunnels: Due to their micrometric measurements, only cell extensions can grow within the microchannels, leaving the cell bodies within the compartments themselves, that allow an enhanced fluidic isolation and discontinuous connectivity between compartments.

NeoBento™ HT Format: The NeoBento is our versatile container which is in the standard 96-well microplate format, compatible with standard liquid handling and imaging equipment, and does not require expensive equipment. The NeoBento™ makes NETRI’s microfluidic devices as versatile and easy to handle as a typical 96-well plate.




.

DuaLink Ultra.

Specially designed for 2 co-cultures & enhanced axonal projection.

With the DuaLink Ultra microfluidic chip, the microchannels grooves and HT format NeoBento™ technologies are combined in a single chip to provid an unparalleled user experience combined with an enhanced axonal projection rate.

• 3 compartments : 2 for cell culture & 1 for fluidic isolation
• 8 or 16 microfluidic chips per NeoBento™
• Co-culture of different cell types
• Enhanced axonal projection and time to results
• Continuous connectivity by microchannels grooves technology





.
All our chips are in the NeoBento™ format (standard 96-well SBS plate format) and thus offer a variety of handling readouts for your different needs.

Imaging
• Immunofluorescence
• Calcium Imaging
• Live staining
• Live Dead Assays
  Biochimic analysis
• Lysis cells analysis
• Supernatant analysis
• ELISA
• Liquid chromatography
• Mass Spectoscopy



.
DuaLink Ultra is specially designed to co-culture 2 cell types in channel 1 and 3 and allow an enhanced axonal projection rate between channels.

In-vitro models
• Peripheral Neuropathic Pain
Indications
• Neurological Troubles (AD, PD, ALS, MS)
• Skin nociception
Field
• Toxicology
• Virology
• Neuroinflammation
• Itch
• Ageing
Capabilities
• Axonal transport
• Co-culture & compartmentalization
.
Our aim is to translate physiological behaviors by integrating our technologies within one chip.

Microchannel grooves: Due to their micrometric measurements, only cell extensions can grow within the microchannels, leaving the cell bodies within the compartments themselves, that allow an enhanced axonal projection rate and continuous connectivity between compartments.

NeoBento™ HT Format: The NeoBento is our versatile container which is in the standard 96-well microplate format, compatible with standard liquid handling and imaging equipment, and does not require expensive equipment. The NeoBento™ makes NETRI’s microfluidic devices as versatile and easy to handle as a typical 96-well plate.




.

DuaLink Delta Ultra.

Specially designed for 2 co-cultures & enhanced growth kinetics.

With the DuaLink Ultra microfluidic chip, the microchannels grooves and HT format NeoBento™ technologies are combined in a single chip to provid an unparalleled user experience combined with an enhanced growth kinetics.

• 3 compartments: 1 for cell culture, 1 for fluidic isolation and 1 to monitor axonal growth
• 8 or 16 microfluidic chips per NeoBento™
• Enhanced growth kinetics
• Triangular shape with microchannels of different length
• Continuous connectivity by microchannels grooves technology





.
All our chips are in the NeoBento™ format (standard 96-well SBS plate format) and thus offer a variety of handling readouts for your different needs.

Imaging
• Immunofluorescence
• Calcium Imaging
• Live staining
• Live Dead Assays
  Biochimic analysis
• Lysis cells analysis
• Supernatant analysis
• ELISA
• Liquid chromatography
• Mass Spectoscopy



.
DuaLink Delta Ultra is specifically designed to monitor growth kinetics between channels 2 and 3 and allow an enhanced axonal projection rate between channels.

In-vitro models
• Motor Nerve Injury
• Sensory Nerve Injury
Indications
• Alzheimer Disease – Tau
• Spinal muscular atrophy
Field
• Neuroinflammation
• Neurodevelopment
• Regenerative medicine
Capabilities
• Axotomy
• Growth kinetics quantification
• Co-culture & compartmentalization
• Axonal transport
Our aim is to translate physiological behaviors by integrating our technologies within one chip.

Microchannel grooves: Due to their micrometric measurements, only cell extensions can grow within the microchannels, leaving the cell bodies within the compartments themselves, that allow an enhanced axonal projection rate and continuous connectivity between compartments.

NeoBento™ HT Format: The NeoBento is our versatile container which is in the standard 96-well microplate format, compatible with standard liquid handling and imaging equipment, and does not require expensive equipment. The NeoBento™ makes NETRI’s microfluidic devices as versatile and easy to handle as a typical 96-well plate.




.

TriaLink Ultra.

Specially designed for 2 co-cultures & enhanced growth kinetics.

With the Link Ultra microfluidic chip, the microchannels grooves and HT format NeoBento™ technologies are combined in a single chip to provid an unmatched user experience combined with the ability to culture up to 3 different cell types.

• 3 compartments for independant 3 different cell type cultures
• 8 or 16 microfluidic chips per NeoBento™
• Up to tri-culture of different cell types
• Continuous connectivity by microchannels grooves technology







.
All our chips are in the NeoBento™ format (standard 96-well SBS plate format) and thus offer a variety of handling readouts for your different needs.

Imaging
• Immunofluorescence
• Calcium Imaging
• Live staining
• Live Dead Assays
  Biochimic analysis
• Lysis cells analysis
• Supernatant analysis
• ELISA
• Liquid chromatography
• Mass Spectoscopy



.
TriaLink Ultra is specially designed to co-culture 3 cell types in channel 1, 2 and 3, and allow an enhanced axonal projection rate between channels.

Indications
• Multiple sclerosis
• Cerebral tumors
Field
• Neuroinflammation
• Gut-Brain-Axis
Capabilities
• Co-culture & compartmentalization
• Axonal transport





.
Our aim is to translate physiological behaviors by integrating our technologies within one chip.

Microchannel grooves: Due to their micrometric measurements, only cell extensions can grow within the microchannels, leaving the cell bodies within the compartments themselves, that allow an enhanced axonal projection rate and continuous connectivity between compartments.

NeoBento™ HT Format: The NeoBento is our versatile container which is in the standard 96-well microplate format, compatible with standard liquid handling and imaging equipment, and does not require expensive equipment. The NeoBento™ makes NETRI’s microfluidic devices as versatile and easy to handle as a typical 96-well plate.




.